Chapter 11 a of the california building code volume 1.
Ada restroom requirements california.
California building code volume 1 chapters 10 and 11b.
If the construction value of the remodel exceeds 161 298 california code requires an upgrade to full accessibility compliance for the building entry path of travel to the area of remodel and restrooms serving the remodel.
Accessible fixtures typically are those that meet certain height requirements.
Ada compliant urinals should be stall type or wall hung at a maximum of 17 inches from the floor.
Ada requires that at least one toilet and one lavatory be accessible in public restrooms.
For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
The recommended symbol comprises a geometric symbol of a triangle superimposed on a circle.
Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty.
Ccr section 11b 403 5 1 exception 1 an unobstructed turning space 27 inches high and at least 60 inches in diameter is required inside the restroom for voters who use wheelchairs.
Under california law however two signs are required for every public restroom a law that predates the 1990 ada.
Ada california building codes requirements.
The minimum width of the restroom accessible path of travel shall be 36 inches and may reduce in width to 32 inches for a length not to exceed 24 inches.
Achievable requirements of title iii of the americans with disabilities act may be limited the actual work of the project.
Water closets must be 17 to 19 inches from the floor measured from the floor to the top of the toilet seat.
Requirements for california ada restroom signs at a national level the ada only requires one sign to identify every public restroom.
At least one accessible restroom for each sex.
If the value of construction is less than 161 298 then 20 of the value of construction must be spent on accessibility upgrades addressed in the following order.
In addition to taking the ada s standards seriously california s state government has set up its own codes and standards.
Hand dryer sensors or buttons must be 38 to 48 inches above the finished floor and dryer units must be accessible for right and left handed users.
Ada bathrooms must have hand dryers that are motion activated or touch free devices.
Ada standards for accessible design can be downloaded from www ada.
Like faucets flush valves shouldn t require tight grasping pinching or twisting of the wrist.
Men s rooms containing urinals require at least one accessible urinal.