For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Ada shower grab bar placement diagram.
Typically grab bars in the shower should be installed 33 to 36 inches from the floor of the bathroom this is according to ada americans with disabilities act standards.
In standard roll in type shower compartments the controls faucets and shower spray unit shall be located above the grab bar but no higher than 48 inches 1220 mm above the shower floor.
Remember to consider all users of the home.
Ada grab bar requirements ada grab bar requirements for shower stalls bath tubs and toilet stalls consult manufacturer s installation instructions for proper installation of specific product.
Grab bars in toilet stall requirements.
But i would strongly recommend to take into consideration the height and physical capabilities of the person you are installing these grab bars for.
Where a seat is provided the controls faucets and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located.
Ada requirements for grab bars in a shower stalls.
A a b b 36 max 915 mm 48 max 1220 mm.
Alternate roll in type shower compartments in alternate roll in type shower compartments grab bars shall be provided on the back wall and the side wall farthest from the compartment entry.
Ada figure 609 3 dimensions for rear grab bar installation.
Vertical grab bars are not yet covered in the ada guidelines however ansi specifies the dimensions shown in the diagram.
Grab bars in toilet stall requirements.
This means a grab bar may need to be at an angle to accommodate persons of varying heights and sizes.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum.
Optimal grab bar placement.
Rear wall grab bars shall be 36 915 mm long and mounted so 24 610 mm are to the transfer side of the toilet and the other 12 305 mm to the wall side.
Before we go any further.
Figure 608 3 2 grab bars for standard roll in type showers.
Figure 37 a 36 in by 36 inches 915 mm by 915 mm transfer stall.
The l shaped shower seat shall be 18 inches 455 mm above the floor measured at the entry.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
The source for the information below is the 2010 ada standards for accessible design.
Ada standards for accessible design can be downloaded from www ada.
Dimensions for grab bars.
The rear grab bar can be split or shifted to the open side to accommodate the required location of the flush control valves.
Horizontal side wall grab bars need to be 42 1065 mm minimum length.
Make sure that your installer is experienced with grab bars and knows about mounting anchor safety and options.