Knee and toe space must be at least 30 wide and up to 25 deep measured to the leading edge of the clear floor space.
Ada vanity sink requirements.
Toe clearance shall extend 25 inches 635 mm maximum under an element.
Compliance date for title ii.
The specifications allow space for plumbing enclosures and supports outside the minimum clearances.
Controls for faucets shall comply with 309.
A knee clearance of 24 inches 610 mm minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches 785 mm maximum above the finish floor or ground.
Most are wall mounted which i didn t want.
State and local government facilities must follow the requirements of the 2010 standards including both the title ii regulations at.
Measurement starts from the point where a person has 9 vertical clearance for their feet and 27 vertical clearance for their knees.
306 2 3 minimum required depth.
The recommended height is no more than 34 inches from the floor.
Bathroom sink requirements to be ada compliant every fixture in the bathroom including the sink must be accessible to a person in a wheelchair.
Faucets should be lever operated push touch or electronically controlled.
There aren t a lot of options out there for ada compliant vanities.
And the 2004 adaag at 36 cfr part 1191 appendices b and d.
They re also very expensive.
This places limits on the height of the sink and its position on the counter.
Sinks must have 30 x 48 760 x 1220 mm of access.
Space under an element between the finish floor or ground and 9 inches 230 mm above the finish floor or ground shall be considered toe clearance and shall comply with 306 2.
In the few places where requirements between the two differ the requirements of 28 cfr 35 151 prevail.
You also need a clear floor space and insulated pipes under the sink.
To meet ada guidelines sinks shouldn t be mounted higher than 34 inches from the floor and they should have a knee clearance of 27 inches high 30 inches wide and 11 to 25 inches deep.
No object can protrude into the required clearances other than the dip of the overflow at lavatories and sinks.
I wanted an ada compliant vanity that would look have legs but still accommodate a wheelchair under it.
In residential dwelling unit kitchens sinks that are adjustable to variable heights 29 inches 735 mm minimum and 36 inches 915 mm maximum shall be permitted where rough in plumbing permits connections of supply and drain pipes for sinks mounted at the height of 29 inches 735 mm.