With wall mounted water fountains there must be a minimum of a 48 inch by 30 inch floor space in front of the unit to allow a wheelchair to make a forward approach.
Ada water fountain approach.
We have outdoor drinking fountains for schools parks and much more.
This series of pedestal drinking fountains include steel stainless steel aggregate historical chilled and sand free.
The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010.
Water coolers and bottle fillers can be provided at or integrated with compliant drinking fountains.
The americans with disabilities act ada requires wall mounted drinking fountain units to have a clear knee space of at least 27 high 30 wide and 17 to 19 deep.
Set your store to see local availability add to cart.
Advisory 602 6 water flow.
Click one of the categories below to filter between our products.
Halsey taylor non filtered 8 gph wall mount ada drinking fountain in platinum vinyl model hac8pv nf 671 52 671 52.
If the water fountain is in an alcove the alcove must be at least 30 inches wide with a 24 inches maximum depth.
Refer to figure d.
These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards or standards.
The purpose of requiring the drinking fountain spout to produce a flow of water 4 inches 100 mm high minimum is so that a cup can be inserted under the flow of water to provide a drink of water for an individual who because of a disability would otherwise be incapable of using the drinking fountain.
On an accessible drinking fountain with a round or oval bowl the spout must be positioned so the flow of water is within 3 in 75 mm of the front edge of the fountain.
New akicon 1 handle copper drinking fountain water faucet model ak7718c 119 99 box 119 99 box free delivery.
Position at most elements clear floor or ground space can be positioned for either a forward or a side approach.
Refer to figure e.
The lower height drinking fountain shall have a 30 x 48 760 mm x 1220 mm clear floor or ground space positioned for a forward approach and centered on the unit.
If a drinking fountain is provided a water cooler bottle filler or nearby sink cannot substitute for either the wheelchair accessible or the standing height drinking fountain in new construction additions or alterations.
Our outdoor drinking fountains provide a wide range of ada accessible fountains.
Knee and toe clearance must be provided.